Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4121208
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Repair Maintenance Of Central Air Cooling System At Command Building At Vayusena Nagar, Nagpur
Last Date For Submission18th May, 2026
Opening Date20 May, 2026
Cost
Document Cost500.00
EMD20000.00
Estimated Cost1000000.00
Location
CityNagpur
StateMaharashtra

Register to see full details

BOQ Items
#ItemQtyUnits
1Material and labourfor preparation of old painted surface of bottom tank of AIR washer chamber size approx 4.5mtr X 1.5mtr X 0.3Mtr by removing all dirt, dust, grease, oil etc and painting complete with two coats of water proof paint of approved colour over a coat of red-oxide primer on entire inside surface of tank complete all as specified and directed . Note:(1) At the time of painting process Cost of opening & refixing of filter pad ,angle or tank nut, bolt ,washers etc included in quoted rate.7.00EACH JOB
2Material and labourfor for Taking down electric motor 30/25 HP 415 volt coupled to blower unit after disconnecting the electrical connection, and earth connections removing from its foundation and transportation to work shop , checking the serviceability of bearing both side of motor , greasing of bearing up to free rotation of shaft of motor greasing on reassemblying the motor complete, reinstallation on foundation, reconnecting back the cable and earth connections and , varnsihing, drying, opening, overhauling , greasing ,Alignment pump/motor poperly authorised mechnical including repair to foundation if required at site etc complete in all respect and starting the pump all as directed. Note:(1) Contractor shall be responsible for maintaining required RPM after repair ,non compliance of speed considered as incomplete repair. (2) Cost of Rewinnding & Bearings shall be measured and paid separately.4.00EACH JOB
3Taking down electric motor 0.5 upto 1 HP 415 volt coupled to pump after disconnecting the electrical connection, and earth connections removing from its foundation and transportation to work shop , checking the serviceability of bearing both side of motor , greasing of bearing up to free rotation of shaft of motor complete, greasing on reassemblying the motor to reinstallation on foundation, reconnecting back the cable and earth connections and , varnsihing, drying, ovening, overhauling , greasing ,Alignment pump/motor poperly authorised mechnical including priming of PVC foot valve etc complete in all respect and starting the pump all as directed. Note :(1) Cost of rewinding , Bearings shall be measured and paid separately under relevent item. (2)Contractor shall be responsible for maintaining required including Priming work for motor for taking out water cellouse pads after repair ,non compliance of speed considered as incomplete repair9.00EACH
4Supply only spare parts for Motr/pump set of capacity 30/25 HP in repair of vide sr item No.1 as follows:- a) Supply only shaft of AHU Motor any make any size as per exiting motor at site of capacty 25/35HP complete.4.00EACH
5b) Supply only check nut including gasket5.00EACH
18th May, 2026

6 Days Left

WhatsApp