Tender ID4516467
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Repair And Replacement Of Earthing Infrastructure And Other Connecting Items At Various Location Under Ge Nagrota
Last Date For Submission3rd Jul, 2026
Opening Date07 Jul, 2026
Cost
Document Cost500.00
EMD99860.00
Estimated Cost4993000.00
Location
CityNagrota
StateHimachal Pradesh

Register to see full details

BOQ Items
#ItemQtyUnits
1M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 40mm bore medium grade GI pipe for earth strip protection and 20 mm bore for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/Transformer as specified and testing on completion for desired result complete all as specified and directed . Note :- Digging for earthing allowed only through man power but not through JCB. 60.00Each Set
2M&L in replacement for earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above Copper plate in alternate layers connected to copper strip 20x3 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm bore medium grade GI pipe for earth strip protection and 20 mm bore for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/ Transformer as specified and testing on completion for desired result complete all as specified and directed. Note :- Digging for earthing allowed only through man power but not through JCB. 15.00Each set
3M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 25X4 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm bore medium grade GI pipe for earth strip protection and 20 mm bore for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed . Note :- Digging for earthing allowed only through man power but not through JCB. 60.00Each
4M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth lead wire 4.0 mm (8SWG) by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm bore medium grade GI pipe for earth strip protection and 20 mm bore for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/ DB box as specified and testing on completion for desired result complete all as specified and directed. Note :- Digging for earthing allowed only through man power but not through JCB. 75.00Each
5Supply and fixing in replacement aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.1025.00RM