Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4352966 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Special Repair For Replacement Of Old Vintage Dg Sets At Dharna Pump House And Waldevi Pump House Under Ge Nrc |
| Last Date For Submission | 25th Jun, 2026 |
| Opening Date | 02 Jul, 2026 |
| Document Cost | 1000.00 |
|---|---|
| EMD | 189000.00 |
| Estimated Cost | 11375000.00 |
| City | Nashik |
|---|---|
| State | Maharashtra |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Taking out unserviceable DG Set 200 KVA from Waldevi Pump House and shifting it to MES Yard at Arty Center complete all as directed by the Engineer - in - Charge. Note :- Quotated rates includes all T & P required for for the shifting of DG Set | 2.00 | Each Job |
| 2 | Taking out unserviceable DG Set 320 KVA from Waldevi Pump House and shifting it to MES Yard at Arty Center complete all as directed by the Engineer - in - Charge. Note :-Quotated rates includes all T & P required for for the shifting of DG Set | 1.00 | Each Job |
| 3 | Supply, installation, testing and commissioning Diesel Engine driven generating set of capacity not less than 200 KVA/ 160 KW, 3 phase, 4 wire, 415 V, 50 Hz,1500 RPM, AC power supply with power factor 0.8 (lagging), coupled directly to alternator, mounted on a common base plate complete with integral acoustic enclosures (shall have salient features) modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB-IV +) latest regulation / norms (NOx+HC < 4.0, CO < 3.5, PM < 0.2 & smoke limit < 0.7 ) with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer complete with necessary PCC foundations PCC foundation as per OEM/ manufacturer recommendation to bear the load of DG set having suitable size including excavation and earth work with block masonry work and plastering all as specified and as directed:- | 2.00 | Each |
| 4 | (I) ENGINE- Efficient CRDI System, designed & tested for 50 degree ambient temperature, Water cooled diesel engine at 1500 RPM, engine capacity suitable for 200 KVA output ,415 V,50 Hz, No of cylinder- 06 Nos consists of direct injection, turbo-charged, four stroke liquid cooled technology confirming to BS : 5514 and IS :10000 suitable for prime duty generating set. Alternator under NTP conditions with provision of 10 % over load for 1 hour confirming to latest CPCB norms .The Engine shall consist of the following:- (a) Dry type air cleaner (b) Exhaust silencer (c) Expansion bellows (d) Lube oil cooler (e) Lube oil filter (f) Radiator, radiator fan and mounting (g) Fuel pump, with governor (h) Fly wheel with starter ring (j) Battery charging alternator with suitable capacity (k) electric starter motor of suitable Volts as per OEM | ||
| 5 | Engine Monitoring system :- The genset monitoring and safety system, having following features :- (a) Controller Microprocessor based ,Graphical LED display,integrated with AMF,Synchorinisation & Communication compatable , Control panel consisting of built in ON/OFF/start key (b) Battery charging voltmeter. (c) Electronic hour meter. (d) Indication & Monitoring of oil pressure & safety trip in case of Low oil pressure. (e) Indication & Monitoring of coolant temperature & safety trip in case of high coolant temperature. (f) In-built engine shut down system in case of engine over speed. (g) Indication & Monitoring of fuel level and alarm. |
6 Days Left