Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4578075
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Provn Of 2 X 30 Kva Ups For Signal Communication And It Infrastructure At Trishakti Complex And Special Repairs / Replacement Of Ups Of Various Capacity And Connected Wks At College Area At Dssc Wellington
Last Date For Submission3rd Jul, 2026
Opening Date10 Jul, 2026
Cost
Document Cost500.00
EMD82200.00
Estimated Cost4140000.00
Location
CityNilgiris
StateTamil Nadu

Register to see full details

BOQ Items
#ItemQtyUnits
1PROVN OF 2 X 30 KVA UPS FOR SIGNAL COMMUNICATION AND IT INFRASTRUCTURE AT TRISHAKTI COMPLEX AT DSSC WELLINGTON
2Supply, install, commissioning & testing of Three Phase, Transformer based Online UPS system of capacity 30.0 KVA with in-built isolation transformer, indoor compact type complete with battery system & battery enclosure suitable for minimum 01 hour back-up & comprising of the following features all as specified & as directed (a) DSP technology with IGBT based inverter. (aa) Inbuilt Over Voltage Cut-Off Device with Surge Protection. (b) Smart LCD display for real-time information. (c) Constant voltage constant frequency operation without battery. (d) EMI/RFI Noise filter. (e) Hot Stand-by & Cold start feature. (f) Built-in maintenance by-pass & static by-pass switches. (g) Inbuilt charger of 20 A. (h) Parallel redundancy & battery reverse protection. (j) Configurable Output Voltage Settings. (k) Over temperature indication & protection. (l) Generator compatible.2.00Each
3Brief technical specifications of the Transformer based Online UPS system are as follows : MODEL : (a) Type & Capacity - Three Phase, 30. KVA/ 24 KW. (b) DC voltage system - 360 VDC. (c) Phase - Three Phase with Ground. INPUT : (d) Nominal voltage - 208/220/230 VAC. (e) Input voltage range - 165 ~ 285 VAC. (f) Frequency range - 40 to 55 Hz. OUTPUT : (g) Output voltage - 208/220/230 VAC. (h) Freq range Battery mode - 50 Hz + 0.1 Hz. (j) AC Voltage Regulation - + 1% (Battery Mode). TRANSFER TIME : (k) AC to Battery mode - 0 ms. (l) Inverter to by-pass mode - 0 ms. (m) By-pass to Inverter mode - <5 ms. (n) Waveform - Pure Sinewave. EFFICIENCY : (o) Overall efficiency (AC mode) - 87%. (p) Efficiency (Battery mode) - 91%. BATTERY & CHARGER : (q) Battery type/No/Make - 12 V, 65 AH/30 Nos/Microteck or Exide for minimum 1 Hour Back-up . (r) Charging current - 2/4/8 A, Default : 8A. BATTERY ENCLOSURE : Battery enclosure shall be MS Powder Coated. INDICATORS : (s) LCD Display - Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode & Fault indicators. (t) Alarms - Battery Mode, Low Battery, Overload, Fault. Make/Model : i-MAXX + series 3 phase input and 3 phase outputTransformer Based Online UPS of make MICROTEK or techno-commercially equivalent of Hitachi i4et / Luminuos / TATA .
4NOTES FOR ITEM NO 1 : 1) Design / drawing / BOM / technical specifications of the complete On-line UPS System incl battery enclosure showing the dimensions is to be obtained from OEM / Auth Channel Partner / Supplier & is to be got approved from Engr-in-charge & GE before placing final order. 2) Techno-commercial comparative analysis is also to be submitted & got approved from Engr-In-Charge & GE whereever techno-commercial equivalency of the product is concerned w.r.t. given Cat/Part/Model/Make ref. 3) The cost of periodical/routine servicing/maintenance including minor repairs/replacement of spare parts (if required) including periodical checking of the complete On-line UPS System for the complete defect liability period (2 Years from certified date of completion of work) from the authorized service dealer/rep as & when required/due is deemed to be included in the unit quoted rates. 4) The complete installation, commissioning & testing of the On-line UPS System is to be got done from the OEM or their auth Rep/Sister Concern/Channel Partners only. 5) Anything missed out in the technical specifications but technically required for efficient working of the On-line UPS System is deemed to be included in the quoted rates. 6) Necessary electric connections/fixing arrangements shall be as per the recommendations of OEM & cost of the same is deemed to be included in the quoted rates.
5S & F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed6.00Each
3rd Jul, 2026

9 Days Left

WhatsApp