Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 3838972 |
|---|---|
| Organisation Name | Greater Noida Industrial Development Authority |
| Tender Brief | Corrigendum : Additional Hvac Work In Indoor Stadium Shaheed Vijay Singh Pathik Sports Complex, Greater Noida. |
| Last Date For Submission | 8th Apr, 2026 |
| Opening Date | 10 Apr, 2026 |
| Document Cost | 1030.00 |
|---|---|
| EMD | 88000.00 |
| Estimated Cost | 4352566.00 |
| City | Noida |
|---|---|
| State | Uttar Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | BOQ | ||
| 2 | Supply, Installation, Testing and commissioning of factory built floor mounted chilled water double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as required, minimum 2 bend GSS/PVC eliminators, cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 10% volts, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, necessary vibration isolation arrangement etc. complete as per specification and of following capacities. 16.26.1 4300 CMH DSR-2018/16.26.7 | ||
| 3 | 13600 CMH | 4 | Nos |
| 4 | INSULATED CHILLED WATER PIPING (expanded polystrene insulation) | ||
| 5 | Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3, grade 1 roofing feltstrip(as per IS:1322 as amended up to date) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. DSR-2018/16.3.10 |
Ending Today