Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4135722 |
|---|---|
| Organisation Name | Shri Vishwakarma Skill University |
| Tender Brief | Corrigendum : Supply/installation Of Required Items List For Physiotherapy Laboratory (major Equipment, Minor Equipment And Other Items) |
| Last Date For Submission | 22nd May, 2026 |
| Opening Date | 25 May, 2026 |
| Document Cost | 2000.00 |
|---|---|
| EMD | 51079.00 |
| Estimated Cost | 0.00 |
| City | Palwal |
|---|---|
| State | Haryana |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Functional Diagnostic Lab (Electro diagnosis Lab) | ||
| 2 | Diagnostic Electrical Stimulator with Facility to draw SD Curve-Frequency Range: 0.1 Hz to 300 Hz (adjustable). Output Current: 0 100 mA with precision adjustment. Waveforms: Rectangular, triangular, sinusoidal pulses, and user-defined patterns. Timer: Adjustable up to 90 minutes with automatic shutoff. Display: Digital high-resolution LCD with graphical representation. Safety Features: Overload protection, short-circuit prevention, and in-built self-diagnostic system. Outputs: Galvanic, Interrupted Galvanic, Faradic, Surged Faradic, TENS. Voltage: Adjustable up to 150V. Pulse Width Options: Multiple, ranging from microseconds to milliseconds. Adjustable Intensity Levels. Audible & visual segment display Electrode pads (reusable and disposable). Conductive gel (hypoallergenic). Elastic electrode straps. | 2.00 | Nos |
| 3 | Biofeedback Unit-Channels: Dual or quad-channel configuration. Frequency Range: 20 Hz to 1 kHz with adjustable gain. Sensitivity: 0.01 V to 500 V. Feedback Modes: Audio, visual, and vibratory feedback options. Power Supply: Rechargeable Li-ion battery and AC adapter. Display: OLED screen for detailed visualization. Provides a measuring range of 0-200 mmHg analog pressure with an accuracy of +/- 3-5 mmHz pressure Use with exercise to protect and stabilize joints, Accessories &Components Reusable electrodes. Adjustable straps. USB-C data and charging cable. | 1.00 | Nos |
| 4 | E.M.G./NCV/EP Unit- Connectivity USB/ETHERNET Channel Minimum 8-10 Input impedance _ above 100 K ohms differential mode, > 1000Mohm in common mode Sensitivity _ 1 micro volt per division to 10 milli volt per division Noise _ < 0.7 micro volt RMS EMG Sensitivity _ High-resolution amplifier with noise reduction. NCV _ Motor and sensory conduction with F-wave and H-reflex. EP: _ Visual, auditory, and somato sensory evoked potentials. Display _ Real-time waveform with analysis tools. Data Storage _ Internal storage with PC connectivity. Power Supply _ 220V AC with battery backup Shielded EP electrodes 10 sets Ground electrodes disc type - 2 sets Ground electrodes strap type(Adult-2 & Pead-2) Recording electrodes cup - 10 sets Ring electrodes & BAR stimulating electrodes- (Adult-2 & Pead-1 each) Conductive paste (3 Jars of 225 gms or more) - 5 sets Skin preparation gel (Set of 2 tubes) - 3 set EMG disposables needles (Box of 25) - 1 boxes (Pead size) EMG disposables needles (Box of 25) - 3 boxes (adult size) Single fibre EMG needle - 2 . (Reusable) Temperature probe - 2 , LED Goggles - 1 Acoustically shielded Head Phones - 1 ) Insert Ear Phones 1 with following buds (Reusable Adult buds 2, Reusable Pead buds 2) | 1.00 | Nos |
| 5 | EXERCISE TOLERANCE AND FITNESS LAB |
6 Days Left