Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Shri Vishwakarma Skill University
Tender ID4135722
Organisation NameShri Vishwakarma Skill University
Tender BriefCorrigendum : Supply/installation Of Required Items List For Physiotherapy Laboratory (major Equipment, Minor Equipment And Other Items)
Last Date For Submission22nd May, 2026
Opening Date25 May, 2026
Cost
Document Cost2000.00
EMD51079.00
Estimated Cost0.00
Location
CityPalwal
StateHaryana

Register to see full details

BOQ Items
#ItemQtyUnits
1Functional Diagnostic Lab (Electro diagnosis Lab)
2Diagnostic Electrical Stimulator with Facility to draw SD Curve-Frequency Range: 0.1 Hz to 300 Hz (adjustable). Output Current: 0 100 mA with precision adjustment. Waveforms: Rectangular, triangular, sinusoidal pulses, and user-defined patterns. Timer: Adjustable up to 90 minutes with automatic shutoff. Display: Digital high-resolution LCD with graphical representation. Safety Features: Overload protection, short-circuit prevention, and in-built self-diagnostic system. Outputs: Galvanic, Interrupted Galvanic, Faradic, Surged Faradic, TENS. Voltage: Adjustable up to 150V. Pulse Width Options: Multiple, ranging from microseconds to milliseconds. Adjustable Intensity Levels. Audible & visual segment display Electrode pads (reusable and disposable). Conductive gel (hypoallergenic). Elastic electrode straps.2.00Nos
3Biofeedback Unit-Channels: Dual or quad-channel configuration. Frequency Range: 20 Hz to 1 kHz with adjustable gain. Sensitivity: 0.01 V to 500 V. Feedback Modes: Audio, visual, and vibratory feedback options. Power Supply: Rechargeable Li-ion battery and AC adapter. Display: OLED screen for detailed visualization. Provides a measuring range of 0-200 mmHg analog pressure with an accuracy of +/- 3-5 mmHz pressure Use with exercise to protect and stabilize joints, Accessories &Components Reusable electrodes. Adjustable straps. USB-C data and charging cable.1.00Nos
4E.M.G./NCV/EP Unit- Connectivity USB/ETHERNET Channel Minimum 8-10 Input impedance _ above 100 K ohms differential mode, > 1000Mohm in common mode Sensitivity _ 1 micro volt per division to 10 milli volt per division Noise _ < 0.7 micro volt RMS EMG Sensitivity _ High-resolution amplifier with noise reduction. NCV _ Motor and sensory conduction with F-wave and H-reflex. EP: _ Visual, auditory, and somato sensory evoked potentials. Display _ Real-time waveform with analysis tools. Data Storage _ Internal storage with PC connectivity. Power Supply _ 220V AC with battery backup Shielded EP electrodes 10 sets Ground electrodes disc type - 2 sets Ground electrodes strap type(Adult-2 & Pead-2) Recording electrodes cup - 10 sets Ring electrodes & BAR stimulating electrodes- (Adult-2 & Pead-1 each) Conductive paste (3 Jars of 225 gms or more) - 5 sets Skin preparation gel (Set of 2 tubes) - 3 set EMG disposables needles (Box of 25) - 1 boxes (Pead size) EMG disposables needles (Box of 25) - 3 boxes (adult size) Single fibre EMG needle - 2 . (Reusable) Temperature probe - 2 , LED Goggles - 1 Acoustically shielded Head Phones - 1 ) Insert Ear Phones 1 with following buds (Reusable Adult buds 2, Reusable Pead buds 2)1.00Nos
5EXERCISE TOLERANCE AND FITNESS LAB
22nd May, 2026

6 Days Left

WhatsApp