Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4409128
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Special Repair To Hard Standing Under Age Br-i And Special Repair And Maint Of Vcb/rmu 33kv,11kv And Connected Works At Mrs And Other Sub Stn Of Power House-2 At Pms
Last Date For Submission23rd Jun, 2026
Opening Date24 Jun, 2026
Cost
Document Cost500.00
EMD67700.00
Estimated Cost3384633.00
Location
CityPANAGARH
StateWest Bengal

Register to see full details

BOQ Items
#ItemQtyUnits
1M&L for servicing / maintenance and calibration of 33 KV VCB outdoor type upto 1250 Amp complete, i.e. IR test, CRM test , Timing Test and Reduce Volatge Test . Disconnecting the main power from 33 KV isolator and control panel of any make type and taking out the breaker parts (any type),cleaning from inside and out side by using CRC-26 spray or any other cleaning agents, greasing the moveable parts.Complete servicing of switchgear including checking the fixed/moving contacts of all the 3 phases adjusting electrical/electronic/mechanical components all as per mfg instruction manual and standard practice. Calibration of relay any type e.g. Earth fault relay/Over current relay,etc of VCB installed at MRS. The fault level setting of these relays shall be in such a way that individual breaker will activate / trip to arrest the fault in local circuit and fault will not travel to main incoming breakers. The servicing & maintenance of 33 KV panel of switchgear shall be carried out through rep of OEM /professional and competent firm / technician / service engineer in this field in the presence of concerned Engr-in-charge and all as per directed.Note :- Contractor will submit testing & calibration report of VCB.The rate quoted by tender shall deemed to include the cost of this provision incl T&P required for VCB calibration and testing. Make-CG/Andrew Yule/Yamuna. Location: MRS. The calibration and servicing shall be carried out by only qualified and experienced person and prior approval shall be obtained from Engr-in-Charge6.00Each
2Supply and fix in replacement of motor drive mechanism wound for 11KV/33KV VCB/bus coupler of existing make, type,size, capacity, with driving gear and springs complete all as specified and directed by Engr-in-charge.3.00Each Set
3S&F in repair open/closed auxiliary contacts for contact multiplication (4NO + 4 NC) 16 Amps,30V DC suitable for upto 1250 Amps HT 11 KV & 33 KV VCB fixed all as specified and directed by Engr-in-charge.4.00Each
4S&F Shunt trip tripping/closing coil assembly 30 Volts, DC suitable for existing sample for 33KV upto 1250 Amps, HT VCB complete incl taking out old assembly of any type and make all as specified and directed by Engr-in-Charge. Make : Seimens or equivalent4.00Each
5S&F Shunt trip tripping/closing coil assembly 110 Volts, DC suitable for existing sample for 33KV upto 1250 Amps, HT VCB complete incl taking out old assembly of any type and make all as specified and directed by Engr-in-Charge.1.00Each
23rd Jun, 2026

6 Days Left

WhatsApp