Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Directorate Of Urban Local Bodies
Tender ID4856308
Organisation NameDirectorate Of Urban Local Bodies
Tender BriefRegarding Supply And Erection Of 10,000 Nos. Of Various Wattages Of Led Street Lights Mc, Panipat. Recall
Last Date For Submission22nd Jul, 2026
Opening Date22 Jul, 2026
Cost
Document Cost5000.00
EMD453000.00
Estimated Cost22622000.00
Location
CityPanipat
StateHaryana

Register to see full details

BOQ Items
#ItemQtyUnits
145 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000 K / 4000 K / 5700 K /6000 K/6500 K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90 C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.11) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix6800.00Each
290watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000 K / 4000 K / 5700 K /6000 K/6500 K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90 C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.14) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix1800.00Each
3120 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000 K / 4000 K / 5700 K /6000 K/6500 K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90 C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.16) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix800.00Each
4150 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000 K / 4000 K / 5700 K /6000 K/6500 K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90 C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.17) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix400.00Each
5200 watt LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy greater then or equal to 120 not more then 135 lm/Watt Supplying, installation, Testing and Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000 K / 4000 K / 5700 K /6000 K/6500 K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90 C). Note: The said description of LED Street Light is taken from amended HSR CHANDIGARH, MONDAY, APRIL 13, 2026 (HSR No. 23.28.13.19) but the said item is not reflection on HEWP portal. So taken as an NS item. Make: Surya/Bajaj/Havells/Phillips/Jaquar/Hallonix200.00Each
22nd Jul, 2026

15 Days Left

WhatsApp