Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4590867
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Provn Of Stabilized 3 Phase Power Supply And Other E M Works In Tech Flt At Air Force Station Pathankot
Last Date For Submission9th Jul, 2026
Opening Date11 Jul, 2026
Cost
Document Cost500.00
EMD87280.00
Estimated Cost4364000.00
Location
CityPathankot
StatePunjab

Register to see full details

BOQ Items
#ItemQtyUnits
1Supply,testing and commissioning indoor L.T.Panel board factory fabricated indoor cubical type totally enclosed made out of 2.0 mm thick sheet metal enclosure with angle iron frame of size 50 x 50 x 06 mm , CPRI approved, IP-42 for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel opening doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands of suitable size for cable entry and exit complete with necessary internal wiring with stranded copper conductor FRLS PVC insulated cables of adequate size, duly with painted one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and aluminium bus bar rating 1500 Amp - 04 Nos mounted on epoxy insulator-01 Set complete with multifunction meter for measuring voltage, current, PF and phase indicating lamp, ammmeter with suitable size of CTs voltmeter, frequecy meter including connecting the following . Incoming:- (a) ACB 1000 Amps 50 KA Four pole 415 volts - 01 No (incomer) IP 54 protection with microprossor based thermal magnetic release (Electrically Draw out type ) with protection By Pass Facility, Shunt & UVT , with breaker ON, OFF, Trip indication Outgoing:- (a) MCCB 630 Amps 50 KA Four pole 415 volts - 02 No (O/G) Double break contact design with adjustable type thermal release FP, with extended terminals & Extended Rotary Handle with breaker ON, OFF, Trip indication (b) MCCB 125 Amps 25 KA Four pole 415 volts - 03 No (O/G) ,Ics=100% Icu ,with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperators (c ) MCCB 100 Amps 25 KA Four pole 415 volts - 02 No (O/G) ,Ics=100% Icu ,with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperators (b) MCCB 63 Amps 25 KA Four pole 415 volts - 03 No (O/G) ,Ics=100% Icu ,with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperators (b) MCCB 40 Amps 25 KA Four pole 415 volts - 02 No (O/G) ,Ics=100% Icu ,with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperators(b) MCB 32 Amps 25 KA single pole and neutral 230 volts - 03 No (O/G) ,Ics=100% Icu ,with fixed magnetic and adjustable thermal release,adjustable overload 80-100%and adjustable short ckt 5 to 10ln setting complete with phase seperators1.00Each
2Supply,installation, testing & commisioning LT Panel board,Indoor type, suitable for operation on 415 volts, AC 3 phase, 4 wire, 50 Hz electric supply system, outer body made out of 2mm thick CRCA sheet, side covers with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated Aluminum busbar duly sleeved with heat shrink sleeve colour coated for 3 Phase, 4 wire electric supply system and control wiring with multistranded PVC insulated copper wire size not less then 1.5 Sqmm, complete comprising with following accessories all as specified and directed by the Engr-in-charge. With MCCB FP 200 Amps 25 KA - 01 No The cost of the PCC foundation shall be deemed to be included in the unit rate quoted for the item..2Each
3Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m.10Each
4Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm single core complete all as specified and directed by engr-in-charge.150RM
5Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3.5 core complete all as specified and directed by engr-in-charge.130RM
9th Jul, 2026

6 Days Left

WhatsApp