Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Department Of Local Government
Tender ID4303797
Organisation NameDepartment Of Local Government
Tender BriefCorrigendum : Estimate For Sewer Line Ward No 30 Arorian Street Patiala. Est Cost Rs. 50.85 Lacs Dt 25/26.05.2026
Last Date For Submission28th May, 2026
Opening Date29 May, 2026
Cost
Document Cost1000.00
EMD101700.00
Estimated Cost5085000.00
Location
CityPatiala
StatePunjab

Register to see full details

BOQ Items
#ItemQtyUnits
1Dismantling concrete Lime concrete, cement concrete of 1:6:12 or leaner mix52.45cum
2Taking out existing CC interlocking paver blocks from footpath/ central verge/pavement, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge521.7672sqm
3FLOORING & DADOS Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibration process or with vibro-hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc., all complete as per directions of Engineer-in-charge IS Code 15658(2006) for Non traffic Areas and streets having width less than 3.05 mt.( Also not to used over footpaths).678.45298sqm
4FLOORING & DADOS Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibration process or with vibro-hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc., all complete as per directions of Engineer-in-charge IS Code 15658(2006) for Non traffic Areas and streets having width less than 3.05 mt.( Also not to used over footpaths).1017.70735sqm
5Excavation of trenches in a Streets, Lanes or in Open Area for Storm Sewers and Manholes to Full Depths as Shown in Drawings,excluding Shoring, Timbering of Poling Board Frame System Type, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines.night signals, profiles, Pegs, Sight rails, boning rods, crossing over trenches for access to the houses, watching, fencing etc., fixing and maintenance of caution boards, refilling trenches, watering of refill in 15 cm layers, ramming and restoration of surface to original conditions and removal of Surplus Spoil from the Site of Works, for all Works other than connections to Ventilating Shafts upto a Lead of 15 mtr for all works other than connections to complete in all respects For depth not exceeding 2 m below ground level All classes of soil except rocky744.58369cum
28th May, 2026

1 Days Left

WhatsApp