| Tender ID | 4779027 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Petty Repairs Of E/m Nature Of Work Switch Socket Submain And Distribution Boxes Including Attending Complaint Day By Day On Emergency Basis At Mil Stn Pithoragarh And Other Connected Area Under Ge Pithoragarh |
| Last Date For Submission | 28th Jul, 2026 |
| Opening Date | 04 Aug, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 40000.00 |
| Estimated Cost | 2000000.00 |
| City | Pithoragarh |
|---|---|
| State | Uttarakhand |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | DESCRIPTION OF ITEMS | ||
| 2 | Attending complaints of electrical nature rectification of the fault as per the complaint lodged by the user onward and including LT Distribution Panel, faults such as decarbonising connections in the DB;s checking for disconnections, loose connection any burning/heating due to overloading in Didtribution boards and restoring electric supply, checking and repair of switch sockets MCB's any type, checking and reconnecting/providing earth connection to distribution boards, checking and rectifying fault including repair/replacement of tubelight fitting any type by replacement of worn out ballast, bipin holder, starter, wom out wire, repair of faulty fan by disconnecting and replacement of unserviceable parts such as capacitor, fan regulator, connecting wires, repair/replacement of lamp holder and wornout holder wire, repair / replacement of electric bell/buzzer/bell push and other internal accessories i.e switch, sockets 5/15 Amps, repair/replacement of short circuited point wiring/sub main wiring, repairs/replacement of recessed light fittings, checking and rectifying earth fault/leakage current in water tap, other home appliances, checking and rectifying faults in building security lights/fittings complete repairs to the extent by removing connections from the system, removing faults in wires, battens, conduit, sunken boxes, juction boxes, main switches, MCBs/DBs utility light fitting, lamp holders ceiling/exhaust fans and other connected fixtures of the internal electrification rectified the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled and nothing extra shall be paid to him, on this account complete all as directed at site to the entire satisfaction of Engr-in-charge/users | 800 | Each Job |
| 3 | Note for srl Item No 01: | ||
| 4 | The Contractor shall provide necessary T&P such as ladder, earth tester, insulation tester, earth megger(500Volts), drill machine, wires of appropriate size and conductor matching to existing one upto the length of 1.5 mtr including insulation tape, screws, nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled and nothing extra shall be paid to him on this account. | ||
| 5 | Attending complaint including taking down/refixing of flouresent tube light fittings/fixture repair shall be mesured against srl item No 01. |