| Tender ID | 3609827 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Servicing Maintenance Of Packages Ac Plant And Miscellaneous Items At Auditorium Cgdhq No 1 Under Ge (i) Cg Porbandar |
| Last Date For Submission | 1st Apr, 2026 |
| Opening Date | 03 Apr, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 16000.00 |
| Estimated Cost | 800000.00 |
| City | Porbandar |
|---|---|
| State | Gujarat |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Schedule 'A' | ||
| 2 | Comprehensive / Preventive maintenance including servicing of 16 HP capacity VRV based air conditioning system outdoor units detail as under installed under GE(I) CG Porbandar for complete contract period detail as under all as specified and directed by Engr-in-charge. Out door unit 16 HP capacity VRF unit of Make -Daikin, Model No - RXYQ16ARY6 Comprehensive / Preventive maintenance of VRF based air conditioning shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge. (a) Testing / Checking of compressor for its proper functioning and rectification of minor defect if any. (b) Testing / Checking of control switch such as pressure cut outs, water flow switch, temprature sensore for proper functioning. (c) Testing / Checking of PCBs of the Indoor unit & Outdoor unit for its proper functioning and rectification of minor defects if any. (e) Testing / Checking of Cooling coil for leakage and Rectification of leakage by brazing including cleaning of Cooling coil. (f) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any. (g) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete. (h) Testing / Checking & servicing of condenser fan motor and rectification of minor defect if any. (j) Testing/Checking of condenser coil for leakage and Rectification of leakage by brezing including cleaning of condenser coil. | 8 | Each Job |
| 3 | (k) Testing / Checking of refrigerant pipe for leakage and Rectification of leakage by brezing including cleaning of refrigerant pipe. (l) Cleaning of entire indoor & outdoor unit for removing all dirt dust, grease etc. Note:- Contrator will carried out Comprehensive / Preventive maintenance including servicing of VRF unit two times during contract period, and shall be measured two times, Contractor shall also be responsible to rectify any defect during break down without any extra cost during contract period. The time interval between both servicing will be intimated by Engineer -in-charge as per requirement. (i) All defective speare parts & compressor etc., if found unserviceable will be measured & paid separately as supply & fix in repair under respective items of This BOQ,. (ii) Topping of refrigerant gas will be measured & paid separately. (iii) The rates quoted by the tenderer shall be deemed to include for any minor repair, which are obviously and fairly, intended which may not have been included in these documents, but which are essential for the execution and entire completion of works. The decision of the Accepting Officer as to what constitutes Minor details of the construction shall be final and binding. (iv) Comprehensive / Preventive maintenance including servicing of VRF unit, & repairing the VRF unit during breakdown / emergency shall be carried out through authorised representative of OEM. Contractor shall submit necessary documentary proof in support of the same. | ||
| 4 | Comprehensive / Preventive maintenance of AHU shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge. (a) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any. (b) Testing / Checking of blower fan blade for proper functioning. (c) Cleaning of cooling coil of AHU unit with pressurised water and then testing/ checking of Cooling coil for leakage and rectification of leakage by brazing including. (d) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete. (e) Testing / Checking and Cleaning the moisture drain pipe. (f) Cleaning of entire AHU unit for removing all dirt dust, grease etc. Note :- contrator will carried out descaling work two time during contract period and shall be measured two times, the time interval between both descaling will intimated by Engineer -in-charge as per requirement . | ||
| 5 | AHU unit 64HP, 13000 CFM capacity, Make -Zeco Aircon Ltd | 2 | Each Job |