Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID5028160
Organisation NameMilitary Engineer Services
Tender Brief81301/e8 Repair/maint Of Central Type Ac Plants And Modular Ot Ac Plant Including Dehumidification System, Ahus, Controls, Ducting And Other Allied Works At Inhs Dhanvantari And Hq 34 Weu Under Age E/m-i Of Ge Minniebay, Sri Vijaya Puram.
Last Date For Submission10th Aug, 2026
Opening Date17 Aug, 2026
Cost
Document Cost500.00
EMD99890.00
Estimated Cost4994500.00
Location
CityPort Blair
StateAndaman and Nicobar Islands

Register to see full details

BOQ Items
#ItemQtyUnits
1M&L for Servicing of the air cooled air conditioning unit (AC Plant) of following capacity by checking the functioning of chiller pump, checking of refrigerant, replenishing refrigerant gas if required, checking of chilled pipe line, condenser pipe line, safety valves, compressor and connected accessories for its proper working and replenishing of compressor oil, checking of microprocessor control panel and replacement of control panel wiring, lubricating the pump sets and fan motor including replacement of bearing and tightening of bolts and nuts complete all as specified and as directed :- Note: (i) The cost of compressor oil, PVC Cable for control panel wiring, grease for lubricating and bearing of motors shall be deemed to be included in the quoted rate. (ii) Refrigerant gas and other spares will be measured and paid separately. (iii) The quoted rate deemed to be include the cost of repair/replacement of defective safety valve of pressure rating 450 PSI all as per existing, repair/replacement of pitted control wiring/lugs/ferrules complete for ensuring proper functionality of AC plant.
270TR (Air cooled type).8Each Job
350TR (Water cooled type).6Each Job
411TR (Air cooled type).24Each Job
5M&L for de-scaling of condenser unit of AC plant by draining condenser water from equipments and pipes, recirculating water inside the pipes with descaling liquid solution(Carbon Tetra Chloride Solution) and flushing out 3-4 times and recirculating fresh water inside the pipes and flushing out five to six times so that descaling liquid is completely cleaned out along with scales from the pipe line complete all as specified and as directed of the following capacity of AC plant are as under:- Note:- Each condenser unit will be measured and paid separately.
10th Aug, 2026

20 Days Left

WhatsApp