Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4242959 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Repair / Maint Of Lt Distribution System With Connected Switchgears, Main Distribution Panels / Pillar Boxes / Panel Boards / Cubicles, Lt Cables And Connected Works At Md Accn Area Of Minnie Bay And Special Repairinagar Area Under Age E/m-i Of Ge Minnie Bay, Special Repair |
| Last Date For Submission | 1st Jun, 2026 |
| Opening Date | 03 Jun, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 87000.00 |
| Estimated Cost | 4350000.00 |
| City | PORT BLAIR |
|---|---|
| State | Andaman and Nicobar Islands |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | M/L for attending LT breakdown complaints/defects from transformer LT terminal box upto Bldg feeder pillar box/DBs with connected switchgears, cables etc complete for making the continuity of supply after rectifying the defects of the electrical network by carrying out with the following scope of work:- (i) cable faults : disconnecting the both ends of cable and check the insulation resistance value.Physical inspection / tracing the cable in cable duct/ trenches. Cutting/disconnecting damaged portion and re-checking for insulation value, and make the cable connection after rectification at both end terminations to restore the power supply. (ii) unserviceable control switch gears / MCCBs / MCB: remove the MCCB/MCB from the panel board and clean the carbonized / burnt surfaces with varnish / CRC solution to make good and fix the new MCCB of suitable rating and connect the cable to MCCB terminals with proper lugging and by applying proper torque to avoid loose connections. spreader links shall be provided if necessary as per site requirement. (iii) Terminals/lugs failure: check for any cable terminal damage / melting by over heating, loose contacts. the damaged portion of cable shall be removed and fixing the lugs and terminate the cable by applying proper torque to avoid loose connections and proper re-distribution of over loading of cable complete all as specifed and as directed. Note :- (i) cable joint kit, MCCB/MCB, lugs and cable fault detection by fault finding machine, any excavation earth work shall be measured and paid seperately under relevant items. spreader links /insulation tape shall be deemed to be included in the rate quoted. (iii) Each Breakdown complaint/defect attended shall be measured as one job through job card. (iv) The contractor shall depute necessary man power on daily basis for rectifying the jobs including sundays and holidays. | 9 | Each Job |
| 2 | M&L for detecting LT UG cable faults located in any stretch/ depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, surge generator of capacity upto 1.1 KV, fault pin point surge wave reciever, cable indentification instrument , cable tracer for exact location of under ground cable routes. Note: The rate quoted deemed to be inclusive of transportation of equipment from any location and charges for service engineer for identifying the fault including their boarding & lodging complete. | 8 | Each |
| 3 | Taking down of old U/s Joit Kit complete all as specified and as directed | 22 | Each |
| 4 | S & F for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5 core complete all as specified and as directed | 2 | Each |
| 5 | S & F for cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm 3.5 core complete all as specified and as directed | 3 | Each |