Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4449253 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Special Repair Of Building No P-414 Army Public School At Brichgunj Mil Stn, Sri Vijaya Puram |
| Last Date For Submission | 26th Jun, 2026 |
| Opening Date | 29 Jun, 2026 |
| Document Cost | 1000.00 |
|---|---|
| EMD | 163500.00 |
| Estimated Cost | 9216810.00 |
| City | PORT BLAIR |
|---|---|
| State | Andaman and Nicobar Islands |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed by Engineer-in-charge. | 350.00 | Sqm |
| 2 | S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge. | 310.00 | Sqm |
| 3 | S&F pre-painted galvalume aluminium zinc coating GI baesd plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge. | 40.00 | Sqm |
| 4 | M & L for water proofing treatment with the following specifications including taking down existing roof treatment of any description and cleaning with water and scrubbing and disposing off the rubbish outside the premises, complete all as specified and directed by Engineer-in-charge and as per manufacturers instructions:- (i) Rendering 10mm thick in CM 1:4 on concrete surfaces mixed with water proofing compouund @ 3% by weitht of cement as leveling course (ii) Apply a coat of hot blown bitumen 85/25 @ 1.20 kg/sqm over a coat of bituminous primer @ 0.3 ltr per sqm. (iii) Laying APP membrane (STP Aquashield or equivalent) weighing not less than 3.5 Kg/sqm, reinforced with polyster non woven fabric (weighing not less than 150 gms/sqm) with 100mm over laps both longitudinally and transversally and overlaps shall be sealed by torch, membrane shall be taken to the parapet through fillet and shall be tucked in inside after a height of 300 mm. (iv) Apply one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm over the membrane. Note :- Water proofing compound shall be measured and paid separately. | 80.00 | Sqm |
| 5 | Dismantling of wall & celling boards (fiber pulp insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets all as specified and directed by Engineer-in-charge. | 400.00 | Sqm |