Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4781108 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Ge (n) P/token- 33 Of 2026-2027 Maint To Arrest Leakage/seepage From Roof, Wall,chajja Of Effected Bldgs For Offrs/jco/or Md Accn And Other Otm Accn At Various Locations/units In The Area Of Age B/r (east) Under Ge (n) Pune. |
| Last Date For Submission | 27th Jul, 2026 |
| Opening Date | 01 Aug, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 70000.00 |
| Estimated Cost | 3500000.00 |
| City | Pune |
|---|---|
| State | Maharashtra |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Complete removal of existing water proofing treatment of any thickness and cement mortar screed in existing roof including scrapping out old treatment/ bitumen etc. The roof surface shall be thoroughly wire brushed, cleaned to eliminate all sharp projections, washed, dried up and cleaned of all foreign material and dust to receive new water proofing treatment and removal of rubbish off the premises to a distance exc. 500m and not exc 1.5 Km complete all as specified and as directed. | 2500 | Sqm |
| 2 | Demolition of cement concrete of any description and in any position not therwise specifically provided for complete all as specified and as directed. | 25 | Cum |
| 3 | M&L for PCC (1:2:4) type B-0 (using 12.5mm graded broken stone aggregate) averaging 50mm thick as in leveling course on roof slab including finishing the surface of concrete even and fair to receive screed complete all as specified and as directed. | 25 | Cum |
| 4 | M&L for cement mortar screed(avg 25mm) of 1:4 ratio in layers to achieve smooth finish surface with adequate slope to prevent stagnation of water on roof, with suitable water proofing compound. | 65 | Cum |
| 5 | M&L for water proofing treatment to RCC roof slab complete all as specified below and as directed by Engineer-in-Charge including testing :-(a) 10mm thick rendering in cement mortar (1:3) mixed with and including integral water proofing compound @ 3% by weight of cement on roof slab finished even and fair complete (b) On the dried plastered surface, one coat of approved bituminous primer @ 0.70Kg/Sqm shall be applied. (c) On this primered surface, APP modified bituminous memberance 3mm thick with non woven polyster mat as reinforcement weighing not less than 3.60 Kg/Sqm with plain finish shall be laid by torch application method (d) Apply two coat of bituminous aluminium paint @ 0.15 Kg/Sqm. (e) The overlap while torching shall be 100mm at the longitudinal edges and 150mm at the ends. (f) The treatment shall be carried as per manufacturer instructions through authorised applicator. Note: Temporary arrangement has to be made for supply of water during roof treatment work. | 2500 | Sqm |
6 Days Left