Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Indian Institute Of Science Education And Research
Tender ID4884699
Organisation NameIndian Institute Of Science Education And Research
Tender BriefCorrigendum : Replacement Of Old Hvac Equipments Of Guest C Wings At Iiser Pune
Last Date For Submission27th Jul, 2026
Opening Date28 Jul, 2026
Cost
Document Cost1180.00
EMD140000.00
Estimated Cost7000000.00
Location
CityPune
StateMaharashtra

Register to see full details

BOQ Items
#ItemQtyUnits
1Cat (A) -Items to be supply and installation: Bidder Please note that, quoted rate are inclusive of tranportation, labour, royalties taxes etc. except GST. GST will be paid as Govt of India, rules and regulation.
2VRF Capacity 12 HP Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50 C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. ISEER value at 100% load for 12 HP VRF system is minimum 4.5 (Make- Carrier/Daikin/Toshiba/Hitachi/Mitsubishi) Warranty period -02 Years2Nos.
3VRF Capacity 16 HP Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50 C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. ISEER value at 100% load for 16 HP VRF system is minimum 4.1 (Make- Carrier/Daikin/Toshiba/Hitachi/Mitsubishi) Warranty period -02 Years2Nos.
4VRF Capacity 20 HP Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50 C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. ISEER value at 100% load for 20 HP VRF system is minimum 4.0 (Make- Carrier/Daikin/Toshiba/Hitachi/Mitsubishi) Warranty period -02 Years2Nos.
5VRF Cassette indoor unit - 2.0 TR Supply, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan / 7.4 DELHI SCHEDULE OF RATES (E&M) Volume-II 2025 82 dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor)35Nos.