| Tender ID | 4295120 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Special Repair To Fire Alarm At Various Locations At Af Stn Pune |
| Last Date For Submission | 10th Jun, 2026 |
| Opening Date | 17 Jun, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 82677.00 |
| Estimated Cost | 4133800.00 |
| City | Pune |
|---|---|
| State | Maharashtra |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supplying, installation, Testing, Commissioning & programing of Microprocessor based Addressable Four loop capacity, Networkable type fire alarm control panel with log history . The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 99 detectors and 99 analog addressable devices in one loop with features Four access levels, capable of taking Flash Scan devices, 240 volts AC power supply, automatic battery charger, 24AH, 2x12 volts sealed lead acid batteries sufficient for 48 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. The panel shall be as per tech specification EN54/UL listed RS 232 communication port and RS 422 Network card complete including relay modular, on front, canfront module, asson modul etc in all respect and dismantling old panle one and all as specified and directed. i) The fire alarm system accessories such as smoke sensor, beam sensor, MCP, Isolator, repeater panel etc shall be of same make and shall be compatible to communicate with control panel. ii) Layout diagram of Fire alarm system shall be submited by contractor for approval of GE, and execution work shall only commence after approval of layout diagram and contractor is bound to execute work as per approved without any financial effect. iii) On installation of the system, entire system shall be tested in presence of user rep and rep of accepting officer. iv) Contractor shall provide display board duly indicating the location of sensor and its specified address. v) Contractor shall provide wiring diagram in site plan of fire alarm cable connected to control panel. * Note : The make of control panel should be similar to the make of Repeater Panel, Manual Call Point (MCP), All detectors and sounder. | 10.00 | Each |
| 2 | Supply and fix adressable smoke Detectors Complying with dule LED and type certified to EN-54 type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360 including addressing. The detector shall be polarity insensitive & smart addressable type having 6 level smoke sensitivity . Mechanical Dipswitch or Rotary addressing type. Operating temperature transient -10 C to 85 C. The detector should have dual polling 360 degree viewable LED with 4 class approved response modes the scope includes fitment of sensor in space between false ceiling & roof including removal of false ceiling as per required to detectors, refixing the false celing after fitment of sensor on roof /false etc cost of the false ceiling repair / replacement/required demed to be included for required and dismantling old detectore as one and all as specified and directed by Engr-In-Charge. | 315.00 | Each |
| 3 | Supply and fix adressable type Flame detectors with UV and IR detection capacity ( add up cost of module to be a complete set, the type of module shall be relay type module as per IS: 11360 including addressing and The detector shall be polarity insensitive & smart addressable type. Mechanical Dipswitch or Rotary addressing type. Operating temperature transient -10 C to 85 C. The detector should have dual polling 360 degree viewable LED with 4 class approved response modes and dismantling old detectore as one and all as specified and directed by Engr-In-Charge. | 2.00 | Each |
| 4 | Supply , fixing and testing Addressable Hooter cum strobe 120Db with Mechanical Dipswitch or Rotary addressing type, LED indication and dismantling old hooter as one and all as specified and directed By Engr-In-Charge. | 32.00 | Each |
| 5 | Supply, install, testing and comissioning of adressable break glass manual call point including sunken boxes, with built in monitor module will all acessories and signal indicator,Mechanical Dipswitch or Rotary addressing type complete as per tech specification and dismantling old MCP as one and shall be UL listed complete. | 32.00 | Each |