Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4618785 |
|---|---|
| Organisation Name | The West Bengal Power Development Corporation Limited |
| Tender Brief | Corrigendum : Procurement Of Complete Set Of Oxygen Analyser Used In Air Pre Heater Inlets And Outlets Of U -3,4,5,6 Under C And I Dept, Ktps. |
| Last Date For Submission | 18th Jul, 2026 |
| Opening Date | 21 Jul, 2026 |
| Document Cost | 0.00 |
|---|---|
| EMD | 71700.00 |
| Estimated Cost | 0.00 |
| City | Purba Medinipur |
|---|---|
| State | West Bengal |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | INSITU ZIRCONIA OXYGEN ANALYZER FOR OXYGEN ANALYSER O2 ANALYZER,PROBE WITH CONVERTER SIGNAL OUTPUT 4-20MA DC,DISPLAY RANGE 0 -100%,HART Additional Data: Complete set of zircinia base oxygen analyser: Probe Length:2 meter, Materials:ss316, Flange:DIN PN10 /ANSI150-DN50A SUS 304 Probe OD:2''. Probe protector: Material:ss316 Flange:DIN PN10/ ANSI150- DN50A SUS 304(COUNTER FLANGE SHOULD BE PROVIDED BY VENDOR) OD:3'',ID:2.5'',Length:2050 mm.Out put signal:4-20 ma dc, Power supply:240 v ac,50 hz. Connecting wires between analyser to converter need to be provided if required, Cable should be minimum 50 metre in length. Transmitter Option : Standard ZIRCONIA BASED, System Type : Remote Probe Type : Standard , No Automatic Calibration, Probe insertion Length : 2.0 metre, Thermocouple Type : Type k, Standard Cell ;,, Accuracy : 0.05% O2,Response Dead Time : 3 sec., Response rate :T90 is less than 10 seconds, Zero drift & Span drift : < 0.2% typically, Output: 4-20mA. | 4 | SET |
| 2 | OXYGEN ANALYSER,ZIRCONIA BASED Additional Data: Complete set of zircinia base oxygen analyser: Probe Length:1 meter,Materials:ss316, Flange:DIN PN10/ANSI150- DN50A SUS 304 Probe OD: 2''. Probe protector: Material:ss316 Flange:DIN PN10/ ANSI150- DN50A SUS 304 (COUNTER FLANGE SHOULD BE PROVIDED BY VENDOR) OD:3'',ID:2.5'',Length:1050 mm.Out put signal: 4-20 ma dc, Power supply:240 v ac,50 hz. Connecting wares between analyser to converter need to provide if required, Cable should be minimum 50 metre in length.Transmitter Option : Standard ZIRCONIA BASED, System Type : Remote Probe Type : Standard , No Automatic Calibration, Probe insertion Length : 1.0 metre, Thermocouple Type : Type k, Standard Cell ;,<(>,<)> Accuracy : 0.05% O2, Response Dead Time : 3 sec., Response rate :T90 is less than 10 seconds, Zero drift & Span drift : <(><<)> 0.2% typically, Output: 4-20mA. ) | 8 | NO |
13 Days Left