Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4789698
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Repair/ Replacement Of Ac, Refrigerator, Water Cooler Geysers Internal Electric Supply Of Building Submain, Db, Ceiling, Exhaust, Wall Mounting, Pedestal Fan And Its Connected Works In Tech And Residential Area Of Irde Under Ge (i) Rnd Dehradun
Last Date For Submission27th Jul, 2026
Opening Date29 Jul, 2026
Cost
Document Cost500.00
EMD76000.00
Estimated Cost3800000.00
Location
CityRaipur
StateChhattisgarh

Register to see full details

BOQ Items
#ItemQtyUnits
1Disconnecting, dismantling and taking out the existing Air conditioner Split type of any description, any make and in any position 1.5 TR/2 TR capacity, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete, all as specified and directed by Engr-in-Charge. Note: (Applicable for Sch A Item No.1). (i) Split type AC's shall be taken from department on "as and where installed" basis. (ii) Split type AC's are to be maintained for heating as well cooling , where this provision is in the machine. (iii) The spare parts measured & paid separately as supply only rates. Rate for fixing of spare parts (ie compressor, condensing coil, cooling coil & blower motor) under relevant items shall be included in item No.1). (iv) The contractor shall ensure and asses at the site any initial maintenance required, to make the all Split type AC's in proper working condition, at the time of taking over and he shall be laible to make all listed handed over units functional. (ii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. 250.00Each Job
2M&L for Repair to existing rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )3.00Each
3Supply only new Rotory type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )5.00Each
4Supply only new Rotory invertor type compressor sealed unit of suitable capacity/ model in the unit properly for 1.5 TR/2.0 TR window/Split type AC complete, all as specified and directed by Engineer-in-Charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )10.00Each
5Supply only new condensing coil unit for Split type AC of any type/ any capacity complete, all as specified and directed by Engr-in-charge. (Make : EMERSON COPELAND /L.G / HITACHI / TECUMSEH )10.00Each
27th Jul, 2026

6 Days Left

WhatsApp