Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4856258
Organisation NameMilitary Engineer Services
Tender BriefSpecial Repair Replacement Of Street Light Timer And Connected Works Provn Of Security Lights At Various Loc Of 3 Corps Zonal Wksp And Provn Of 30 Kva Stabilizer Of Building No T 10 In M Zone At Rms
Last Date For Submission27th Jul, 2026
Opening Date29 Jul, 2026
Cost
Document Cost500.00
EMD92000.00
Estimated Cost4600000.00
Location
CityRANGAPAHAR
StateNagaland

Register to see full details

BOQ Items
#ItemQtyUnits
1S&F in replacement nature switch smart timer based automatic street light control panel, suitable enough to take three phase load for 12-15Kw, 32 Amps per phase with Hensal enclosure, confirming to IP-66 (Navdeep 66 series Nature switches)complete with timer, contactor, relays and incoming outgoing MCBs complete all as specified and as directed.8.00Each
2S&F in replacment nature switch smart timer based automatic street light control panel, suitable enough to take single phase load for 5-7kW, 32 Amps per phase with Hensal enclosure, confirming to IP-66 (Navdeep 66 series Nature switches)complete with timer, contactor, relays and incoming outgoing MCBs complete all as specified and directed.37.00Each
3M&L for Earthing complete with galvanized steel earth plate 60cm x 60cm x 6mm thick electrode, burried directly in ground (earth pit not less than 2.70 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI SWG wire 6mm dia size up to test point by means of nuts, bolts, check nuts and washers of GI, with and including excavation and earth work, PCC (1:3:6) type C-1 pit, 20mm bore dia GI pipe medium grade pipe for watering arrangement and 15mm bore dia GI pipe, light grade for protection of earth wire, 50mm thick RCC (1:2:4) type B-1 cover, reinforced with 8mm dia TMT bars @ 15cm C/C both ways and with handle made out of 10mm dia bars, funnel, wire mesh etc. as shown in electrical Plate No. 03 of SSR Part-I connected to earthing test point including taking down old unserviceable material and testing on completion complete all as specified and as directed. Note : The all earthing pits resistance result is must to maintain within site required range.47.00Each Set
4M&L for Earth continuity conductor or main earthing lead fixed to wall/pole on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6mm dia galvanised iron or steel wire complete all as specified and directed. .200.00Rm
5Supply, laying and testing XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.1980.00Rm
27th Jul, 2026

20 Days Left

WhatsApp