Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Military Engineer Services
Tender ID4244380
Organisation NameMilitary Engineer Services
Tender BriefRepair/ Maintenance Of Lt Distribution System And Allied Works At Mudfort, Hanuman Temple, Havelock Line, Ncc, Sappers Line, Ce(fy), Rcph And Adjoining Area Under Age Em Ii Of Ge(u) Secunderabad
Last Date For Submission1st Jun, 2026
Opening Date08 Jun, 2026
Cost
Document Cost500.00
EMD96000.00
Estimated Cost4800000.00
Location
CitySecunderabad
StateTelangana

Register to see full details

BOQ Items
#ItemQtyUnits
1M&L for attending, repair and rectification of external LT electric supply complaints on up to 1100 Volts grade, over head/ underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:-
2Replacement of worn out jumpers, jointing and tightening with new ACSR conductor. Note:- Single phase/ two wire or 3 phase/ 4 wire system will be considered as one job for payment purpose.30.00Each
3Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply. Note :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately. (ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.30.00Each Job
4Notes for Item Nos 1.01 to 1.02 :- (a) The contractor will be allotted complaints at MES complaint cell on daily basis on all working days and sufficient resources will be deployed by him/ her for completion of day to day complaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. (b) A detailed log of complaints with completion/ non-completion remarks from users/ MES will be maintained by the contractor and the same will be updated on daily basis in consultation with Engr-in-Charge or JE E&M as detailed. (c) The contractor will make suitable arrangement for emergency complaints and will notify auth rep/ Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints. (e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad. (f) The contractor will maintain location wise record of each spare utilized as per inventory format given by AGE E/M, Secunderabad and the same shall be submitted to E/M No II store on daily basis.
5M&L for ACSR conductor, steel reinforced for LT over head lines on poles including stretching tightening of poles insulator with binding wire of suitable size with insulator/ stretching of ACSR conductor including disconnecting/ taking out old existing unsv ACSR conductors complete all as specified and directed.2.00Qtl
1st Jun, 2026

20 Days Left

WhatsApp