Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4857037 |
|---|---|
| Organisation Name | Housing And Urban Development Authority |
| Tender Brief | Sh Co Adminstrative Block And Workshop Block Providing Internal E I Work Therein |
| Last Date For Submission | 15th Jul, 2026 |
| Opening Date | 15 Jul, 2026 |
| Document Cost | 5900.00 |
|---|---|
| EMD | 145270.00 |
| Estimated Cost | 7263358.00 |
| City | Shimla |
|---|---|
| State | Himachal Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed Steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. and approved by the Engineer-in-Charge. Group c. | 760 | Per Point |
| 2 | Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed medium class PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required and approved by the Engineer-in -Charge. | 12 | Per Point |
| 3 | Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed pvc conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. and approved by the Engineer-in-Charge. | 967 | Per Rmt |
| 4 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed pvc conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required and approved by the Engineer-in-Charge. | 806 | Per Rmt |
| 5 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed pvc conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. and approved by the Engineer-in-Charge2x1.5 Sq. mm. | 1500 | Per Rmt |
8 Days Left