Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Housing And Urban Development Authority
Tender ID4857037
Organisation NameHousing And Urban Development Authority
Tender BriefSh Co Adminstrative Block And Workshop Block Providing Internal E I Work Therein
Last Date For Submission15th Jul, 2026
Opening Date15 Jul, 2026
Cost
Document Cost5900.00
EMD145270.00
Estimated Cost7263358.00
Location
CityShimla
StateHimachal Pradesh

Register to see full details

BOQ Items
#ItemQtyUnits
1Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed Steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. and approved by the Engineer-in-Charge. Group c.760Per Point
2Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed medium class PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required and approved by the Engineer-in -Charge.12Per Point
3Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed pvc conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. and approved by the Engineer-in-Charge.967Per Rmt
4Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed pvc conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required and approved by the Engineer-in-Charge.806Per Rmt
5Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed pvc conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. and approved by the Engineer-in-Charge2x1.5 Sq. mm.1500Per Rmt
15th Jul, 2026