| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Material and labour for replacement of Cable jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified and as directed by Engr-in-Charge. | 5.00 | Each |
| 2 | Material and labour for Servicing of Vacuum Circuit Breaker and calibration of HT VCB panel including VCB 800/630/400 Amps, after taking proper shut down and disconnecting the cables from panel and VCB Breakers, calibration of over fault relay, earth fault relay, checking of alignment of VCB isolating contacts, rewiring of burnt out/unsv VCB panel wiring complete, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decorbonising of panel, bus section & circuit section including incoming/outgoing cable and necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of burnt out/defective spares like tension springs, tortion springs, nut bolts, washers of suitable size, lingers etc., under the supervision of expert technician of ground or authorised dealer/ representative, and refixing the panel in its original position with complete painting of VCB Panel and testing entire satisfaction of Engineer -in- Charge . | 50.00 | Each Job |
| 3 | Note: (i) The quoted Rate shall be deemed to include all minor spares etc as directed by Engr-in-Charge. (ii) If any burnt out/defective items like moving/fixed contacts, tripping coils,earth fault relay, etc., will be measured and paid separately under respective items. (iii) Spare parts required other than mentioned here-in-after shall be deemed to be included in the quoted rate. (iv) Contractor will inspect de-carbonizing moving and fixed contacts, lubricating, inspecting the wiring of Micro processor Earth Fault and Over Current relays, tripping coil electrical, indication systems, metering systems and checking for manual/auto tripping system, meggaring all the contacts and placing back the breaker trolley in its original position paid separately under relative item as supply only. However fixing charges shall deemed to be included in this item (v) Major Spare parts shall be (vi) A sum of Rs. 2000/- will be recovered from the contractor for non rectification of breakdown/fault or replacement of any unserviceable spares after 12 hours from lodging of complaint telephonically or verbaly (vii) Caliberation testing to be introduced to be done through OEM and Testing certificate of Calibration should be submitted by contractor after caliberation of VCBs | ||
| 4 | Note:- (viii). All Vacuum Circuit Breaker are 11 KV of Capacity 400/630/800 Amps or as per Ground (ix). Make of existing Vacuum Circuit Breakers are Yamuna Power/ ABB/ CG/ ITE/ SIEMENS. | ||
| 5 | Suppy only in Replacement of fixed contact block complete suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps of Make Yamuna Power/ ABB/ CG/ ITE complete all as specified and as directed by Engr-in-Charge. | 8 | Each |