Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Electricity Department
Tender ID3902628
Organisation NameElectricity Department
Tender BriefCorrigendum : Supply Of 11kv And 33 Kv Outdoor Oil Cooled Metering Unit (combined Ct And Pt Set) Under South Andaman Division Sub-division.
Last Date For Submission4th May, 2026
Opening Date05 May, 2026
Cost
Document Cost0.00
EMD22210.00
Estimated Cost1110380.00
Location
CitySOUTH ANDAMAN
StateAndaman and Nicobar Islands

Register to see full details

BOQ Items
#ItemQtyUnits
1Supply of 11kV & 33 KV Outdoor Oil Cooled Metering Unit (combined CT & PT set) under South Andaman Division sub-division.
211kV Outdoor Oil Cooled CTPT Combined unit 50 Hz Three Phase Six Bushing Type with Three no. CT and One no. Three Phase VT with HV neutral broughtout and earthed ILV 12/28/75 kVp Ins Class A, Ref Std Ref Std IS16227- 1&4 CT Specification: Ratio 80-40/5A Class 0.5 Burden 15VA ISF<=7.5 @ 40A STC 4kA Time: 1 Sec. VT Specification: Ratio 11kV/110V Class 0.5 Burden 100VA Voltage Factor 1.2 Continuous/1.5 for 30 Seconds Vector Group/Connection Star/Star (YNyn0). Terminals: Brass Stud Type Primary Terminals M12 in size with Nut, Plain Washer, Spring Washer & Check Nut. Without Terminal Connector. Minimum Creepage Distance 25mm/kV. Note :Primary Neutral to be Solidly earthed. Finish: Tank Painted Colour Shade 631 as Per IS5.1.00Nos
333kV Outdoor Oil Cooled CTPT Combined unit 50 Hz Three Phase Six Bushing Type with Three no's CT and Single No's Three Phase VT with HV neutral brought out and earthed ILV 36/70/170 kVp Ins Class A Ref Std IS16227-1&4. CT Specification: Ratio 25/5A Class 0.5 Burden 15VA ISF<=7.5 STC 4kA Time :1Sec. VT Specification: Ratio 33kV//110V Class 0.5 Burden 100VA Voltage Factor 1.2 Continuous/1.5 for 30 Seconds Vector Group/Connection Star/Star (YNyn0).Terminals: Terminals: Brass Stud Type Primary Terminals M12 with Nut, Plain Washer, Spring Washer & Check Nut. Without Terminal Connector. Minimum Creepage distance 25mm/kV Note: Primary Neutral to be Solidly earthed. Finish: Tank Painted Colour Shade 631 as Per IS5.1.00Nos
433kV Outdoor Oil Cooled CTPT Combined unit 50 Hz Three Phase Three Bushing Three nos. CT's and One no. Three Phase VT with HV neutral broughtout and earthed. ILV 36/70/170 kVp Ins Class A , Ref Std IS16227-1&4. CT Specification: Ratio 25/5A Class 0.5 Burden 15VA ISF<=7.5 STC 4 kA Time : 1Sec. VT Specification: Ratio 33kV//110V Class 0.5 Burden 100VA Voltage Factor 1.2 Continuous/1.5 for 30 Seconds. Vector Group/Connection Star/Star Terminals: Brass Stud Type Primary Terminals M12 with Nut, Plain Washer, Spring Washer & Check Nut. Without Terminal Connector. Minimum Creepage distance 25mm/kV Note: Primary Neutral to be Solidly earthed. Finish: Tank Painted Colour Shade 631 as Per IS5. 1.00Nos
533kV Outdoor Oil Cooled CTPT Combined unit 50 Hz Three Phase Three Bushing Three nos. CT's and One no. Three Phase VT with HV neutral broughtout and earthed. ILV 36/70/170 kVp Ins Class A , Ref Std IS16227-1&4. CT Specification: Ratio 25/5A Class 0.5 Burden 15VA ISF<=7.5 STC 4 kA Time : 1Sec. VT Specification: Ratio 33kV//110V Class 0.5 Burden 100VA Voltage Factor 1.2 Continuous/1.5 for 30 Seconds. Vector Group/Connection Star/Star Terminals: Brass Stud Type Primary Terminals M12 with Nut, Plain Washer, Spring Washer & Check Nut. Without Terminal Connector. Minimum Creepage distance 25mm/kV Note: Primary Neutral to be Solidly earthed. Finish: Tank Painted Colour Shade 631 as Per IS5. 1.00Nos
4th May, 2026

9 Days Left

WhatsApp