| Tender ID | 4369019 |
|---|---|
| Organisation Name | Public Works Department |
| Tender Brief | Corrigendum : Creation Of Central Lab And Canteen In Stilt Floor Of Ipd Block At Skims Mch Bemina (mechanical Component-sitc Of Vrv/vrf System) |
| Last Date For Submission | 8th Jun, 2026 |
| Opening Date | 08 Jun, 2026 |
| Document Cost | 1500.00 |
|---|---|
| EMD | 87000.00 |
| Estimated Cost | 4334000.00 |
| City | Srinagar |
|---|---|
| State | Jammu and Kashmir |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be 6.4 as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 and complete the ODU must deliver a COP of minimum 3.5 at full load and shall be suitable to operate within an abmbient temperature of range of 5 deg. C to 40 deg.C in cooling mode to 15 deg. C in heating mode | ||
| 2 | Outdoor Unit- 18HP (Hot And Cold) Top Discharge Canteen= 1w | 1 | Job |
| 3 | Outdoor Unit- 16HP (Hot And Cold) Top Discharge labs and allied rooms = (2w +1s) | 3 | Job |
| 4 | Design,Supply, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump,drain pipe, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V 10%, 50Hz AC supply, complete, as required. The Indoor units must shut down upon receiving a singal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor) | ||
| 5 | 1 TR Room2 = 01 No. | 1 | each |