| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Construction of SNCO Transit Accn (Aircrew) with toilet (made up of RCC framed structure as per codal provisions) of size Bldg - 4 rooms of size 4mx4mx3.20mtr height & Toilet - 4 Nos of size 2.20mx1.80m x3.20 complete all as shown on drawing and all as specified. The structural design of bldg needs to be prepared and also to be vetted from NIT or IIT by the contractor. Certificate from IIT/NIT in their letter head needs to be in conjunction with codal provns and submitted by the contractor before execution of the work. Design criteria: The structure shall be designed in accordance with relevent IS Provns/NBC code/ extant govt guidelines suitable for Thoise, however, some of design criteria are listed as under: (a) Seismic Co-efficient:As per Seismic Zone IV. (b) Snow load :As per IS codal provn applicable at Thoise. (c) Wind load :Equivalent to wind speed of min 55 mtrs/sec or as per relevent IS applicable at Thoise . (d) Roof slope: as per design requrement. (e) Design load: As per IS 875/Relevent IS provn. (f). Design of foundation as vetted by the auth as mentioned above. | 1.00 | Each Job |
| 2 | (g) SBC of nearby area is roughly 15Ton/sqm at a depth of 1.5m . However, Contractor shall untertake actual SBC of site and shall be approved by GE in case the SBC is less than 15Ton/Sqm the foundation design shall be accordingly modified and shall be got approved from GE . The quoted rate is deemed to be included. (h) The FFL should be 450mm above the GL and subsequent filling and PCC work must be included in the quoted rates by the contractor. (l) RCC Work of M30 Design mix should be considered in Thoise Area. (A) Dimension Data. (i) SNCO Transit Accn (4 Nos Rooms) (a) Length : 4.00 M. (Inner Wall to Inner Wall) (b) Width : 4.00 M. (Inner Wall to Inner Wall) (c) Height : 3.20 Mtr from FFL. (ii) Toilet (a) Length 2.20 M. (Inner Wall to Inner Wall) (b) Width : 1.80 M. (Inner Wall to Inner Wall) (c) Height : 3.20 Mtr from FFL. (B) Foundation shall be designed by the tenderer and quoted rate is deemed to include the same (Design Cost). All the items i.e. Exavation for foundation/PB, removal/refilling of soil, PCC Work in fdn, Reinforcement/RCC work, formwork are deemed to be included in the quoted rate for this item. | ||
| 3 | (C) Column : shall be designed by the tenderer and quoted rate is deemed to include the same (Design Cost). All the items i.e. Reinforcement/RCC work, formwork are deemed to be included in the quoted rate for this item. (D) Beam (Plinth Beam, Lintel Beam & Room Beam) & Roof Slab : shall be designed by the tenderer and quoted rate is deemed to include the same (Design Cost). All the items i.e. Reinforcement/RCC work, formwork are deemed to be included in the quoted rate for this item. (E) Wall: Pre-cast cement concrete block masonry with solid blocks type B1, 1:2:4 (20 mm graded stone aggregate) and setting in cement mortar 1:4, complete all as specified and are deemed to be included in the quoted rate for this item. (For thickness of wall ref arch drg). (F) Rendering : (a) External Rendering 15 mm thick (in two layer of 10 mm and 5 mm) on precast concrete block masonry/Concrete surface in cm 1:4, finished even and smooth without using extra cement, using water proofing compound complete all as specified and are deemed to be included in the quoted rate for this item. NOTE: WPC should be added as per manufacturing instruction or 3% of weight of cement. | ||
| 4 | (b) Internal Rendering 15 mm thick on fair faces of precast concrete block masonry surface in cm 1:6, finished even and smooth without using extra cement complete all as specified and are deemed to be included in the quoted rate for this item. (c) Rendering 5 mm thick on fair faces of roof slab, soffits of slab surfaces in cm 1:3, finished even and smooth without using extra coment complete all as specified and are deemed to be included in the quoted rate for this item. (G) Flooring/Wall Tiling-: (i) SNCO Transit Accn Bldg ( Living Rooms) : 75 mm thick, Plain cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough over Hardcore 100 mm thk : (Broken stone boulders) of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers, watered and rolled/rammed to a true surface over rammed earth filling under floor are deemed to be included in the quoted rate for this item. (ii)Varandah : Non Skid ceramic joint free coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, over and including15 mm thick screed bed in cm 1:4 in floors etc. set and joint free in neat cement slurry and pointed in white or coloured cement to match complete over sub base : 75 mm thick, Plain cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough over Hardcore 100 mm thk : | ||
| 5 | (Broken stone boulders) of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers, watered and rolled/rammed to a true surface over rammed earth filling under floor are deemed to be included in the quoted rate for this item. (iii) Toilet (Floor & Wall tile): (a) Non skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, over and including15 mm thick screed bed in cm 1:4, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete over sub base : 75 mm thick, Plain cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough over Hardcore 100 mm thk : (Broken stone boulders) of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers, watered and rolled/rammed to a true surface over rammed earth filling under floor are deemed to be included in the quoted rate for this item. (b) Glazed ceramic coloured tiles in vertical surface 300X 200 7mm/ 450X 300X 7mm thick upto height 2.10mtr set over 10 mm thick rendering in CM 1:4 and jointed in neat cement slurry and pointed in white or colour cement to match, complete all as specified and as directed by Engr-in-Charge. |