Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4907937 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Repair/replacements/rewinding Of Summer Appliances (all Weather Ac, Refrigerator, Voltage Stabilizer, Exhaust Fan) And Routing Day To Day Maintenance And Other Connected Works At Af Stn Thoise And Siachin Base Camp Under Ge (af) Thoise |
| Last Date For Submission | 5th Aug, 2026 |
| Opening Date | 07 Aug, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 32000.00 |
| Estimated Cost | 1600000.00 |
| City | Srinagar |
|---|---|
| State | Jammu and Kashmir |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | M&L for Charging of refrigerant Gas R-32 in split type Air conditioner (All weather) of capacity 1.5/2 Ton after flushing the complete system with CTC (Carbon tetra choloride) including S & F and replacement of filter/stainer and capillary, vacumise the complete system with vacuum pump and testing on after charging gas all as specified and directed. | 17.00 | Each |
| 2 | M&L for Charging of refrigerant Gas R-32 in window type Air conditioner (All weather) of capacity 1.5/2.0 Ton after flushing the complete system with CTC (Carbon tetra choloride) including S & F and replacement of filter/stainer and capillary, vacumise the complete system with vacuum pump and testing on after charging gas all as specified and directed. | 19.00 | Each |
| 3 | M&L for Charging of refrigerant Gas R-134/R-134a and any uses of Gas in Deepfreezer/upright chiller/ freezer/ Refrigirater after flushing the complete system with CTC (Carbon tetra choloride) including S & F and replacement of filter/stainer and capillary, vacumise the complete system with vacuum pump and testing on after charging gas all as specified and directed. | 11.00 | Each |
| 4 | M&L for shifting of window/Split Air conditioner by safely removing it from existing location including making good to disturbed surfaces matching with existing and storing refrigerant gas securely and refixing the same at new location, providing proper insulation to Copper tubing and extention of existing copper tubing, providing mounting brackets for indoor and outdoor units including testing after shifting complete all as specifed and directed by Engr-In-Charge. | 6.00 | Each Job |
| 5 | M&L in replacement of condensing coil made out of copper tubing with aluminum fins including brazing to unit and leak testing suitable for 1.5/2.0 Ton window/split AC as per sample complete all as specified and directed by Engr-In-Charge. | 4.00 | Each |
6 Days Left