Complete Tender Details

Empowering Indian businesses in the procurement ecosystem since 2012

Tendering Authority: Local Self Government Department
Tender ID4829051
Organisation NameLocal Self Government Department
Tender BriefAnnual Plan-psnm School Peroorkada Rewiring-psnm School Peroorkada Repair Maintanace And Rewiring The Existing Electrical Installation To The Old School Building.-
Last Date For Submission9th Jul, 2026
Opening Date10 Jul, 2026
Cost
Document Cost1960.00
EMD22174.00
Estimated Cost886953.00
Location
CityThiruvananthapuram
StateKerala

Register to see full details

BOQ Items
#ItemQtyUnits
1PSNM School Peroorkada repair maintanace and rewiring the existing electrical installation to the old school building.
21.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A65.000point
31.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B48.000point
41.11:Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.2.000point
519.1:Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required:6.000each
9th Jul, 2026

5 Days Left

WhatsApp