Tender ID4258361
Organisation NameIndian Institute Of Science Education And Research
Tender BriefCorrigendum : Providing Aluminium Partition Work In Vfr Ground Floor And Basement Floor In Iiser Campus, Vithura
Last Date For Submission22nd May, 2026
Opening Date23 May, 2026
Cost
Document Cost0.00
EMD3808.00
Estimated Cost190403.00
Location
CityThiruvananthapuram
StateKerala

Register to see full details

BOQ Items
#ItemQtyUnits
1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
2For Fixed Portion Powder coated aluminium (minimum thickness of powder coating 50 micron)100.28Kg
3For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)30.00Kg
4Providing and fixing glazing in aluminium/wooden door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket/wooden beading etc. complete as per the architectural drawings and the directions of engineer-in-charge.With float glass panes of 6.0 mm thickness (weight not less than 10kg/sqm)13.00sqm
5Supply and applying of approved shade of frosted film as per the design in the designated areas. The surface preparation should be made before the installation in order to attain a smooth finish. The films should be installed towards the clean surface with the help of recommended patch tools etc., as required. The films should be fixed towards the glass in the designated area as per the design and comments from the engineer-in-charge. Total glass area covered without deduction of cut patches/design will be considered for payment101.00sqm