| 1 | STRAIN GUAGE CHARACTERISTICS KIT
AC mains power supply:230 V +10%, 50 Hz, Metal foil strain gauge mounted on beam/cantilever, Strain measurement under applied load, Wheatstone bridge arrangement, Signal Conditioning and amplification circuit, Instrumentation amplifiers with 3 digit display for strain/output voltage ,Zero and gain adjustment controls, Provision for applying calibrated loads, Table-top trainer with labelled panel, Test points for signal measurement, Built-in DC power supplies and wooden closed cabinet, Supplied with patch chords | 1 | Nos. |
| 2 | LOAD CELL CHARACTERISTICS KIT
Input supply :230 v /50 Hz ac with regulated internal DC supply,
Sensor: strain gauge load cell with suitable mounting arrangement ,
Load range: 0-10Kg ,
Display: digital display for load/output indication,
CRO/test points: Test points provided for observing bridge output, amplifier output, and signal conditioning stages,
Controls: Zero adjustment and calibration controls provided, Protection: Overload and short -circuit protection provided ,Accessories: Loading arrangement, connecting leads | 1 | Nos. |
| 3 | MEASUREMENT OF TANK LEVEL USING ROTOMETER
Input supply: 230 v/50 Hz with regulated internal DC supply ,Tank Arrangements: Transparent tank with 30 liters capacity with suitable supporting stand, Rotameter range: 0-4000 L/ hr calibrated rotameter, Flow system: pump, control valves, and piping arrangements provided for continuous flow operation ,Measurement facility: provision for flow -based tank level measurement and observation ,Display/observation: calibrated level indication with flow monitoring arrangement, Test points: output terminals provided for monitoring sensor /output signals , Accessories: connecting tubes | 1 | Nos. |
| 4 | MEASUREMENT OF TEMPERATURE USING PT 100:
Input supply : 230 v/50Hz ac with regulated internal DC power supply unit , Sensor: PT 100 resistance temperature Detector (RTD) probe with stainless steel sheath, Measurement principle: Resistance variation of platinum element with temperature, Temperature Range : 0 OC to 150OC (or suitable laboratory range ),Display unit: Digital temperature indicator with direct OC display, Accuracy: High accuracy with linearized RTD signal conditioning circuit, Signal conditioning: Built -in bridge circuit with amplifier and linearization ,Test points: Provided for RTD input, bridge output, amplifier output, and final display signal, Controls: Zero and span calibration adjustment for temperature calibration , protection: Over-voltage and short circuit protection for electronic modules , Accessories: Temperature bath or heater arrangement, connecting cables, user manual, and circuit diagram included. | 1 | Nos. |
| 5 | TEMPERATURE MEASUREMENT TRAINER WITH PT 100, NTC, TC:
Input supply: 230 v/50Hz ac with regulated internal DC power supply unit, sensors provided: PT 100 RTD,NTC thermistor, and thermocouple(TC-K type), Measurement principle: Resistance variation (PTC &NTC) and see back effect (thermocouple), Temperature Range: suitable for laboratory range (0OC to 150OC or higher depending on sensor), Display unit: Digital temperature indicator with selector switch for PT 100/NTC/TC, Signal conditioning: separate condition circuits for RTD bridge, thermistor network, and thermocouple amplifier, Test points: provided for sensor input ,conditioned output, and final display signal, Controls: sensor selection switch, zero/ span calibration , and temperature adjustment control, Protection : over- voltage and short circuit protection for electronic modules , Accessories: Heating source or temperature bath connecting leads | 1 | Nos. |