Tender BriefCorrigendum : Repair Replacement Of Conventional Light Fittings To Led Light Fittings, Building Security Light And Its Allied Works At 39 Wing Af Stn Udhampur
Last Date For Submission17th Apr, 2026
Opening Date20 Apr, 2026
Cost
Document Cost500.00
EMD90000.00
Estimated Cost0.00
Location
CityUdhampur
StateJammu and Kashmir

Register to see full details

BOQ Items
#ItemQtyUnits
1M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Surface conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
2One light/Fan/Exhaust fan point controlled by one switch285.00Per Point
3S&F switch piano, flush type, 5 amps single pole, one way285.00Each
4M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 1.50 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 1.50 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface / concealed PVC conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Note: Two runs each of 1.50 sqmm main cable and one RM of 1.50 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.450.00RM
5S&F in repair Recess mounting type fitting LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 36 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, Surge Protection>2 KV, IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified.80.00Each