Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4952875 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : Special Repair To Water Proofing Treatment To Roof Of Kv Building And Provn Of Drain At Pm Shri Kendriya Vidyalaya Varangaon Under Ge(s) Ahilyanagar |
| Last Date For Submission | 10th Aug, 2026 |
| Opening Date | 12 Aug, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 98000.00 |
| Estimated Cost | 4895000.00 |
| City | Varangaon |
|---|---|
| State | Maharashtra |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | M&L for brickwork with fly ash bricks (old size), straight or curved on plan, exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and as directed. | 156.00 | Cum |
| 2 | Demolition of brick work or stone/block masonry, built in cement or cement lime mortar of any description complete all as specified and as directed. | 1.00 | Cum |
| 3 | Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for all as specified and as directed | 1.20 | Cum |
| 4 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and as directed. | 1.00 | Cum |
| 5 | M&L in repairs, for water proofing treatment to RCC roof slab, including parapet, comprising with the following treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc and disposal of rubbish not exceeding 1km distance from starting point. (ii) Screed bed or bedding layer of 10 mm thick cement mortar 1:4 with mixing of WPC as per manufacturers instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3kg/sqm. (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.30 ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.6 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying two coat of bituminous aluminium paint over the APP modified membrane @ 0.11Kg/sqm. Note: Cost of Water proofing compound shall deemed to be included in the quoted rate. | 3500.00 | Sqm |
6 Days Left