Empowering Indian businesses in the procurement ecosystem since 2012
| Tender ID | 4779045 |
|---|---|
| Organisation Name | Military Engineer Services |
| Tender Brief | Corrigendum : 8668 Special Repairs To Roof And Connected Works At Signature Management Centre (smc) Building At Nstl Visakhapatnam |
| Last Date For Submission | 27th Jul, 2026 |
| Opening Date | 31 Jul, 2026 |
| Document Cost | 500.00 |
|---|---|
| EMD | 19800.00 |
| Estimated Cost | 987000.00 |
| City | Visakhapatnam |
|---|---|
| State | Andhra Pradesh |
| # | Item | Qty | Units |
|---|---|---|---|
| 1 | Taking down existing roof treatment of any description including roof plaster and removing the debris to a distance exc. 500m and depositing out side MD land all as directed. | 550.00 | Sqm |
| 2 | (a) M& L for mechanical cleaning of surface to make it free from any bituminous residue /dirt, oil and Greece etc all as specified and directed by GE/Engr-in-Charge. (b) M&L for cracks treatment by cutting open cracks and cleaning it from dirt/loose materials etc and filling with polyurethane based sealant with and including application of PU based primer all as directed by GE/Engr-in-Charge . (c) M&L for applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of primer of same materials after dilution of water at 50% or specific primer matching same materials and 2nd, 3rd coat consisting 100% of polyurethane material. After 2nd coat, spread non-woven geo-textile of 45 gsm with overlaps of 50mm in both directions when the surface is still stacky as per manufacturer specification and as directed by GE/Engr-in-Charge. Properties of Polyurethane based chemical shall confirm to following Technical Parameters:- (i) Highly Elastic. (ii) UV Resistance. (iii) Adhesion to concrete. (iv) Tensile strength not less than 2.0 N /Sq.mm for free film. (v) Elongation not less than 300%. (vi) Solid content by weight- not less than 60% (vii) Air/water permeability BSEN 12390 at 5 bar -72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0 mm. (viii) Accelerated weathering (ASTM453) : Pass 1000 hours. (ix) Reaction to fire non inflammable. | 550.00 | Sqm |
| 3 | M&L Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes Cement plaster 1:3 | 550.00 | Sqm |
| 4 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets | 215.00 | Sqm |
| 5 | Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum)With Semi perforated 12mm thick micro tegular edged GRG false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance edged GRG thick square edged of 99%, NRC0.50 to 0.75 as per IS false ceiling GRG false ceiling 8225:1987, Noncombustible as per BS4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- Charge. | 215.00 | Sqm |