Tendering Authority: Military Engineer Services
Tender ID3677620
Organisation NameMilitary Engineer Services
Tender BriefCorrigendum : Day To Day Maintenance Call On Repairs For 24 Hrs Of Lt Panels Jbs Pbs Cps And Attending Breakdown And Allied Works At Jetty Substation And Jetty Area At Naval Dockyard Visakhapatnam Under Ge (i) (dm) Visakhapatnam
Last Date For Submission8th Apr, 2026
Opening Date10 Apr, 2026
Cost
Document Cost500.00
EMD93280.00
Estimated Cost4664000.00
Location
CityVisakhapatnam
StateAndhra Pradesh

Register to see full details

BOQ Items
#ItemQtyUnits
1Attending day to day work and breakdown and call on repair for uninterupted shore power supply cope points, Junction boxes, Pillar boxes, LT cables off sizes, earthings, cable joints etc complete by providing daily minimum 02 electrician and 02 helper during the complete work period all as specied and directed here-in-after:- Note: (a) Contractor shall not claim for outsourcing350.00Each Job
2(b) Work will be measured as per unit specified M&L for finding of cable fault inside Jetty gallery or any jetty supply interruption by disconnecting both cable ends, using insulation tester, cable fault finder and rectification complete by cutting at fault position, fixing of straight through heat shrink joint, for cable sizes 150 sqmm to 500 sqmm, 3.5 core, 1100 volts grade and reconnection of both cable end to original position, replacement of defective aluminium cable lugs, fixing with old or required new nuts-bolts-washers complete with testing all as specified and directed. (c) Items required for rectification such as Heat shrink cable end terminals / straight through joints / heat shrink sleeves shall be measured separately as supply only. (d) Required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.
3M&L for de-carbonizing/cleaning of LT 415/380 V 3 phase Air Circuit Breaker at Pillar boxes inside/above Jetty Gallery by removing outer door, inner door, by draw-out movable unit from base, keeping aside carefully, removing all cable connection from rear side bus, interconnection bus between main bus and ACB, checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC and re-fixing moving unit of ACB, cables, bus the same after applying Backtol (red) solution to the bus bar insulator and replacement of defective aluminium cable lugs and tightening the nuts, bolts, spring washers & thimbles all as specified and directed. Note :- (a) required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate (b) all cleaning agents are included in the quoted rate. (c) Disconnection and reconnection of cable will measured separately50.00Each Job
4M&L for de-carbonizing/cleaning of LT 415/380 V 3 phase, 4 wire Junction boxes inside Jetty Gallery used for distribution of power to different pillar boxes by removing cover, by dismentling bunch of cable termination of 3ph+N busbar (cable terminations are not less than 16 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and and refixing all cable connections, replacement of damaged cable lugs and replacement of damaged nuts, bolts, washers and tightening of all nuts, bolts including one coat of painting to inside chamber of cope point with synthetic enamel paint all as specified and directed. Note: (a) Required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only, (b) Required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.25.00Each Job
5M&L for de-carbonizing/cleaning of complete LT 415/380 V 3 phase Pillar boxes inside/above Jetty Gallery by removing cover, by dismentling bunch of cable termination of 3ph+N busbar from inside gallery (cable terminations are not less than 4 nos in each phase of 150 sqmm to 500 sqmm) taking out aluminium/copper complete busbar off sizes, checking for any defects due to any flush, loose contact and cleaning of complete bus with CTC, replacing damaged coloured heat shrink sleeve, cleaning of all bus insulators and re-fixing bus etc after applying Backtol (red) solution to the insulator and refixing all cable connections, replacement of damaged cable lugs and tightening the nuts, bolts, washers including one coat of painting to inside chamber of cope point with synthetic enamel paint all as specified and directed. Note: (a) required aluminium or copper busbars, coloured heat shrink sleeve for busbar, cable kits, will be measured as supply only, (b) required busbar insulators, aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate.45.00Each Job