| 1 | Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, as per IEC-61349, Platform Mounted, Dust and Vermin proof LT Feeder Panel Board, cubical type, Compartmentalised, fabricated with 3.15mm thick CRCA Sheet duly powder coated, out door canopy type with lifting hooks, consisting of Aluminium bus bar 400 Amps rating (04 Nos) for R-Y-B Phase and Neutral of high conductivity Aluminium and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain/ SMC insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size etc with double stud hinged door, front and back opening, handles on each door with locking arrangement and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 shade, The panel shall be mounted on and including 150mm thick PCC 1:3:6, type C-2 and panel fixed with legs minimum 450mm long made of angle iron frame of size 50x50x5mm including connecting up with existing incoming and outgoing cables, disconnecting and dismantling old panel board complete including and comprising of the following:- | 1.00 | EACH
JOB |
| 2 | [a] Onload Changeover switch I-O-II open execution, 4 Pole, 200 Amps 01 No. [To be fixed after incomer]
[b] MCCB, 200 Amps, TMD type 4 Pole, 415 V, 25 KA, adjustable thermal release- 02 Nos as incomers [Mains+DG]
[d] MCCB, 100 Amps, TMD type 4 Pole, 415 V, 25 KA, adjustable thermal release- 04 Nos [Outgoing]
[e] Three line multifunction meter having LCD display - 01 No
[f] Current Transformer and Potential Transformer - 01 Set
[g] Colour Coded LED Phase Indicating Lamps for each Phase 03 Nos (R, Y, B) | | |
| 3 | Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, as per IEC-61349, Platform Mounted, Dust and Vermin proof LT Feeder Panel Board, cubical type, Compartmentalised, fabricated with 3.15mm thick CRCA Sheet duly powder coated, out door canopy type with lifting hooks, consisting of Aluminium bus bar 1500 Amps rating (04 Nos) for R-Y-B Phase and Neutral of high conductivity Aluminium and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain/ SMC insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size etc with double stud hinged door, front and back opening, handles on each door with locking arrangement and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 shade, The panel shall be mounted on and including 150mm thick PCC 1:3:6, type C-2 and panel fixed with legs minimum 450mm long made of angle iron frame of size 50x50x5mm including connecting up with existing incoming and outgoing cables, disconnecting and dismantling old panel board complete including and comprising of the following:- | 2.00 | EACH
JOB |
| 4 | [a] MCCB, 630 Amps, TMA type 4 Pole, 415 V, 36 KA, adjustable thermal release- 01 No [Incomer]
[b] MCCB, 400 Amps, TMA type 4 Pole, 415 V, 36 KA, adjustable thermal release - 01 No [Outgoing]
[c] MCCB, 250 Amps, TMD type 4 Pole, 415 V, 25 KA, adjustable thermal release - 02 Nos [Outgoing]
[d] MCCB, 200 Amps, TMD type 4 Pole, 415 V, 25 KA, adjustable thermal release - 01 No [Outgoing]
[e] MCCB, 100 Amps, TMD type 4 Pole, 415 V, 25 KA, adjustable thermal release - 02 Nos [Outgoing]
[f] Three line multifunction meter having LCD display - 01 No
[g] Current Transformer and Potential Transformer - 01 Set
[h] Colour Coded LED Phase Indicating Lamps for each Phase 03 Nos (R, Y, B) | | |
| 5 | Supplying, Installing, Commissioning and Testing of CPRI Prototype tested, Factory made, as per IEC-61349, Platform Mounted, Dust and Vermin proof LT Feeder Panel Board, cubical type, Compartmentalised, fabricated with 3.15mm thick CRCA Sheet duly powder coated, out door canopy type with lifting hooks, consisting of Aluminium bus bar 850 Amps rating (04 Nos) for R-Y-B Phase and Neutral of high conductivity Aluminium and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain/ SMC insulator supports, suitable double Compression Copper Cable Glands and panel shall be provided with separate compartments for each switch, with gland plates, lifting hooks, shutter type ventilating louver at both top & bottom duly internally secured with wire mesh, with suitable internal wiring with copper cable of suitable size etc with double stud hinged door, front and back opening, handles on each door with locking arrangement and shall be given pre-treatment for degreasing, phosphatising etc. in seven tank process and shall be powder coated with RAL7035 shade, The panel shall be mounted on and including 150mm thick PCC 1:3:6, type C-2 and panel fixed with legs minimum 450mm long made of angle iron frame of size 50x50x5mm including connecting up with existing incoming and outgoing cables, disconnecting and dismantling old panel board complete including and comprising of the following:- | 3.00 | EACH
JOB |