| 1 | Supply, Installation, Testing & Commissioning of armoured 06 Core Singlemode (OS2) 9/125 Fiber Cable, ITU G.652.D/ G.657A1, Outdoor Corrugated ECCS Armor, HDPE (UV) Sheathing, Theoxtropic gel filled OFC cable with 2 Nos steel wire embedded in side sheathing as strengthening member for switch connectivity. Cable should be ROHS compliant and as per ANSI/TIA-568.3-D, Telcordia GR-20, IEC 60794-2/60794-3-10, ISO/IEC 11801, ISO/IEC 24702 complete on surface / recess / in existing pipe / open duct complete etc as required. | 65000.0000 | Mtr |
| 2 | Supply, Installation, Testing & Commissioning of 12F 1U x 19 LIU Loaded with Singlemode OS2 LC Adapters & LC Type LSZH Pigtails should meet IEC 61034-1 ,IEC-60332-1, IEC-60754-1, Insertion loss <= 0.35 dB, Return Loss >= 50, Attenuation: 1310/1550 : 0.3/0.2 dB/KM, Repeatability: <= 0.2DB 1000 times mating cycles along with Spilce tray, cable holder and 4 nos of cable entry exist point with rubber gurment along with the LIU, SPCC Powder Coated, 2-Cut Out type, 1U, RoHS Complied, Meets ANSI/TIA 568.3-D. etc complete as required.
| 92.0000 | Nos. |
| 3 | Supply, Installation, Testing & Commissioning of 24F 1U x 19 LIU Loaded with Singlemode OS2 LC Adapters & LC Type LSZH Pigtails should meet IEC 61034-1 ,IEC-60332-1, IEC-60754-1, Insertion loss <= 0.35 dB, Return Loss >= 50, Attenuation: 1310/1550 : 0.3/0.2 dB/KM, Repeatability: <= 0.2DB 1000 times mating cycles along with Spilce tray, cable holder and 4 nos of cable entry exist point with rubber gurment along with the LIU, SPCC Powder Coated, 2-Cut Out type, 1U, RoHS Complied, Meets ANSI/TIA 568.3-D. etc complete as required.
| 8.0000 | Nos. |
| 4 | Supply, Installation, Testing & Commissioning of LC-LC 9/125 m OS2 Singlemode Round Cord duplex, LSZH fiber patch cord having a protective layer of metal braiding for LIU to switch connectivity. Patch Cord should have 1000 time mating cycle complete etc as required.
| 200.0000 | Nos. |
| 5 | Supply, Installation, Testing & Commissioning of Networking Horizontal Armoured CAT6 U/UTP Cable having 23 AWG solid bard Electrolytic Grade Copper Conductors, Unshielded Twisted 4 Pair, PVC, Electrolytic Chrome-coated Corrugated Steel Tape Armoring covered with PE Outer Sheath. Category 6, confirming to ANSI-TIA 568.2-D for Category 6 & ISO/IEC 11801 for Class E.Also complying to ISO/IEC 11801 ed. 2.2; IEC 61156-5 2nd Ed.; EN 50173-1; EN 50288-6-1; TIA 568-C.2; Fire rating: IEC 60332-1; IEC 60754-2; IEC 61034; 1-250 MHz (Minimum).
| 9800.0000 | Mtr |